Renault Clio: Refrigerant circuit: Draining - Filling
AIR CONDITIONING or CLIMATE CONTROL

IMPORTANT
Consult the safety and cleanliness advice and operation
recommendations before carrying out any
repair (see 62A, Air conditioning, Air conditioning:
Precautions for the repair, 62A-1).
WARNING
Consult the device's operating manual to avoid
incorrect use.
WARNING
To avoid damaging the cold loop components (corrosions,
etc.), do not use dye if the traces reveal
that some product has already been injected.
Note:
A summary table gives the quantities of refrigerant
in the system according to the engine type (see
62A, Air conditioning, Air conditioning: Parts
and consumables for the repair, 62A-2).
I - RECOVERING REFRIGERANT FLUID
Note:
- If the air conditioning circuit is fitted with a single
filler valve, some filling equipment only
requires the use of the high pressure pipe (refer
to the filling station instructions).
- Depending on the situation, run the system for
a few minutes before recovering the coolant to
improve drainage.
Note:
It is essential to follow these procedures to prevent:
- gas escaping when the circuit is opened,
- pollution of the environment through the release
of gas into the atmosphere when the circuit is
opened or when a vacuum is created.
When draining or checking the refrigerant fill load,
three scenarios are to be taken into account:
- the engine is running and the air conditioning is in
operation (A),
- the engine is running but the air conditioning is not
in operation (B),
- the engine is not running nor is the air conditioning
in operation (C).
Scenario A:
- Operate the air conditioning until the cooling fan
assembly is triggered twice,
- Switch off the engine,
- drain for the first time (note down the original value),
- wait 15 minutes,
- check that the relative pressure is no more than 0
bar,
- repeat the cycles until the relative pressure is equal
to or less than 0 bar,
- add together the values of the various draining operations;
the fill is confirmed as being correct if the
volume of refrigerant fluid is the specified fill +35g
or -100g.
Scenario B:
- run the engine until the cooling fan is triggered
twice,
- Switch off the engine,
- drain for the first time (note down the value),
- wait 15 minutes,
- run the engine until the cooling fan is triggered
twice,
- Switch off the engine,
- drain for the second time (note down the value),
- repeat the cycles until the relative pressure is equal
to or less than 0 bar,
- add together the values of the various draining operations;
the fill is confirmed as being correct if the
volume of refrigerant fluid is the specified fill +35g
or -100g.
Scenario C:
- drain for the first time (note down the value),
- wait 2 hours,
- repeat the cycles until the relative pressure is equal
to or less than 0 bar,
- add together the values of the various draining operations;
the fill is confirmed as being correct if the
volume of refrigerant fluid is the specified fill +35g
or -100g.
II - CREATING A VACUUM
Scenario A:
- creation of a vacuum takes 20 minutes.
Scenario B:
- creation of a vacuum takes 45 minutes to eliminate
any trace of moisture.
- Test the seal once the vacuum has been created
(some stations do this automatically).
III - FILLING
- Fill up the refrigerant circuit using the refrigerant
charging station.
- Top up the oil with the recommended type and volume
of oil and refrigerant, depending on the work
carried out (see 62A, Air conditioning, Air conditioning:
Parts and consumables for the repair, 62A-2).
- Check there are no leaks using the electronic detector
(see 62A, Air conditioning, Refrigerant circuit:
Check, 62A-9).
WARNING
After injecting dye into the refrigerant, be sure to
indicate this on a label (supplied with the dye
capsule), and the date of the operation.
Position the label so it is visible near to the cold
loop filler valve.
- Check that the air conditioning system is operating
correctly (see 62A, Air conditioning, Air conditioning:
Check, 62A-6).
READ NEXT:
AIR CONDITIONING or CLIMATE CONTROL
Note:
Before removal, use DIALOGYS to check how the
condenser is fitted and arranged.
There are 2 possibilities:
the condenser and cooling radiator cannot be se
AIR CONDITIONING or CLIMATE CONTROL
IMPORTANT
To avoid all risk of damage to the systems, apply
the safety and cleanliness instructions and operation
recommendations before carrying out any
repair:
AIR CONDITIONING or CLIMATE CONTROL
IMPORTANT
To avoid all risk of damage to the systems, apply
the safety and cleanliness instructions and operation
recommendations before carrying out any
repair:
SEE MORE:
Speed-dependent
timed rear screen
wiper
With the ignition on, turn the end of
stalk 1 to align mark 2 with the symbol.
Wiping frequency varies with speed.
When working in the engine
compartment, ensure that
the windscreen wiper stalk
is in the park position.
Risk of i
K9K
K9K, and 764 or 766 or 768 or 772
First fitting of the exhaust gas cooler recirculation
assembly
(1) Exhaust gas recirculation solenoid
valve
(2) Exhaust gas cooler
(3) Exhaust gas inlet pipe
(4) Metal air inlet tube
(5) Cooler support on the flywheel
end
(6) Cooler support on the timing
side
S